Input Transfer Flow
Overview:
Transfer Flows are flow time series assignments to pre-defined mass transfers.
Tables:
INPUT_TRANSFER_FLOW
The transfer flow table assigns time series flows to transfers, The table assigns a time series data source to the boundary condition.
Field Descriptions
TRANSFER_NAME
This must be the same as the name of the transfer.
FILLIN
Method for filling in data if the time step of the assigned series is coarser than the time step of the model. See fillin types
FILE
DSS or text file in which data are stored. Use consistent case when referring to the same file. You may also enter the word constant if you would like to assign a constant value to the input (the value will be entered in the next column).
PATH
The path within the text or DSS file of the time series data. If you used the constant keyword in the Input File column, enter the value (e.g. 4.22) here.
Table Info
Identifier:
NAME
Include Block:
HYDRO_TIME_SERIES
Only one flow (and no concentration) can be assigned to a transfer.