Skip to content

Channel Initial Condition

Overview:

HYDRO requires water surface and flow initial condition. This view allows the user to specify default initial conditions. The default initial condition is required. The default will be overridden if a restart file is used.

Tables:

CHANNEL_IC

The table pairs channel locations with default initial values. Interpolation is used between locations. Water surface (stage) and flow must be specified at the upstream and downstream ends of the channel.

Field Descriptions

CHAN_NO

Channel number of channel where initial condition is to be applied.

DISTANCE

Distance along channel where initial condition is to be applied. This may be a numerical distance or the keyword "length" to indicate the end of the channel. If you edit an entry that says "length", you may see a complicated coded value, which is only for internal use.

STAGE

Initial water surface elevation.

FLOW

Initial flow (cfs).

Table Info

Identifier:

CHAN_NO, DISTANCE

Parent Table:

Table is parent

Include Block:

INITIAL_CONDITION


  • Default initial values specified in the GUI are replaced if a restart file is used.
  • Reservoir initial surfaces should be matched to the surrounding channels. Differences imply a flow, and if you haven't accounted for the flow in your other initial conditions you will have a flow imbalance or even instability on the first step.