DSM2 inputs are off by 1DAY
DSM2-241 - Check daily inflows and warn if INST-VAL Open
A problem was reported with a run that was supposed to be a historical run with inflows scaled up by a factor.
On February 14, 1992, both the scaled up flow and stage outputs are higher than historical. |
2. The problem was caused by the "Type" of the scaled up flow input tine series. The user had created a series with a type of INST-VAL. This results in changes in inflow taking effect at the end of the day rather than the beginning of the day. One way to tell that a 1DAY time series is PER-AVER vs INST-VAL is that HEC-DSSVue plots PER-AVER time series as a square wave, but not INST-VAL.
|
---|---|
3. To check Type and to change it, in HEC-DSSVue, right click on the series and select Edit, and use the dropdown to select a new type. |
4. After re-running with the change, results are as expected.
|
Attachments:
image2020-1-15_8-19-11.png
(image/png)
image2020-1-15_8-20-52.png
(image/png)
image2020-1-15_8-21-6.png
(image/png)
image2020-1-15_8-29-2.png
(image/png)
image2020-1-15_8-19-39.png
(image/png)